Technical Profile
Introduction
7SL-3500 3U-VPX
The 7SL-3500 VPX System is a modular Military Rugged ATR enclosure, geared for 3U OpenVPX designs. The versatile design allows multiple customizable configurations based on proven components and design techniques. 7SL-3500 Hybrid conduction cold plate assisted by forced air sets with aggregate power demands over 300W , assisted by liquid up to 600W. Custom and standard 5 to 6 slot backplanes with VPX and SOSA aligned slot profiles in combinations supporting high speed signal processing applications. Scalable to multi CPU-GPU-FPGA requirements Designed expressly for Gen 4.0 ultra-high wattage military systems.
7StarLake scalable and customizable, rugged VPX ATR System enables compute-intensive, SWaP constrained mission-critical applications for deployment in the world’s most demanding military and aerospace environments.
7StarLake Advanced Thermal Solutions
From ships at sea to high-altitude Drone, 7StarLake ATS solutions enable
electronics survivability in the harshest environments. As an ever-increasing number of data acquisition methods are utilized in military and aerospace, the need to convert that rising data tide into precise, real-time action only escalates.
Applications like object targeting , ground vehicles tracking, thermal image monitoring, and multiple simultaneous sensors feeds. When a wealth of such sources need aggregation and immediate analysis, potentially with graphical visualization output to any number of displays, VPX-based systems can ensure proven solutions.
Conduction Cooled_7SL-3500CC
Conduction cooled SBC have traditionally been deployed in applications where heat evacuation with an airflow is impractical.
- As the most common heat-transfer device available, heat pipes can manage the transfer of heat between two solid interfaces effectively. Combining the advantages of thermal-conductivity and phase transition, heat pipes are extremely light-weight compared with traditional cooling methods.
- For the highest thermal dissipation and thermal density, heat pipes can be very effective in conduction cooled environments.
- The heat pipes are embedded in a symmetrical topology from the sidewall, allowing the assembly to be less sensible to gravity or acceleration.
- 7SL-3500 Hybrid conduction cold plate assisted by forced air sets with aggregate power demands over 300W
- Internal recirculation fans ensure dry air is forced across conduction or air-cooled payload modules, minimizing hot-spots and dissipating heat homogeneously
Liquid Cooled_7SL-3500LC
Advanced conduction liquid cooling systems that enables higher powered, compact electronics in ruggedized military, aerospace applications.
7SL-3500-LC is a VPX-REDI Liquid-cooled enclosure utilizing
side-wall cooling within the enhanced wedge-lock guide rails
(increased 50% contact area) cooling of standard conduction
Liquid Cooling Hardware Implementations. In order to effectively
reduce overall temperature and prevent the leakage of the liquid,
7StarLake innovated a unique heat exchanger which integrating
Conduction Liquid Cold Plate (C.L.C.P.) building in most advanced
” Gun Drilled “, which with 4 pipes (each pipe 10mm x 10mm x
400mm) to dissipate max 1KW heat on the 3/4 ATR system.
Product Appearance