Specifications
System | |
---|---|
Processor | Intel® Xeon® Processor D-2796NT (Frequency 2.0GHz, Turbo Boost Frequency up to 3.1GHz), 20 Core, 40 Thread, 30MB Smart Cache |
Memory type | 4x Up to 512GB LRDIMM/256GB RDIMM, 4CH DDR4 2933MHz |
Chipset | SoC, integrated with CPU |
GPU | |
NVIDIA | NVIDIA RTX A2000 |
TFLOPS | 8 |
CUDA Cores | 3,328 |
Memory | 6GB/12GB GDDR6, 192-bit, 288 GB/s |
Graphics Output | |
1x VGA | ASPEED AST2600 |
Resolution | Up to 1920×1200@60Hz 32bpp |
Storage | |
HDD/SSD | 2x 2.5″ 2TB MLC SSD |
100GbE | |
NVIDIA | Nvidia ConnectX-6 Single Port QSFP56 LAN card |
Front and Side I/O | |
X1 | 1x DC-IN, with D38999 connector |
X2 | 1x IPMI, with D38999 connector |
X3 | 1x 100GbE MPO SFP28, with D38999 connector |
X4 | 1x USB3.0, with D38999 connector |
VGA | D-sub15 connector with waterproof cap |
Button | 1x Power Switch with Dedicated LED |
Dedicated LED | 2x Red/Green LEDs ( SSD) |
Power Requirement | |
Power Input | DC-DC 18V~ 36V (300W max) MIL-STD 461 |
Applications, Operating System | ||
---|---|---|
Applications | C4ISR, Commercial and Military Platforms Requiring Compliance to MIL-STD-810 Process Control, where Harsh Temperature, Shock, Vibration, Altitude, Dust and EMI Conditions | |
Operating System | Windows 10 64Bit, Windows Server 2019 64bit, Windows 2016 64bit, Hyper-V Server 2016 R2, Ubuntu16.04.3 LTS/17.10/18.04.1LTS, Fedora 25/26, RedHat Linux EL 6.8/6.9/7.3/7.4/7.6, VMware ESXi 6.5u1 ,Vmware ESXi 6.7U2 | |
Physical | ||
Dimension | 220 x 400 x 177mm (W x D x H) | |
Weight | 15Kg (33.06lbs) | |
Chassis | Aluminum Alloy, Corrosion Resistant | |
Finish | Anodic aluminum oxide | |
Cooling | Natural Passive Convection/Conduction Cooling. No Moving Parts Ingress Protection | |
Ingress Protection | IP65 | |
Environmental | ||
Operating Test MIL-STD-810 | ||
Low air pressure | Method 500.5 | Operation/Air Carriage 4572m (15.000 ft) |
Procedure 2 | ||
Low Temperature | Method 502.5 | -20°C, 4 hours, ±3°C |
Procedure 2 | ||
High Temperature | Method 501.5 | +55°C, 4 hours, ±3°C |
Procedure 2 | ||
Humidity | Method 507.5 | 85%-95% RH without condensation, 24 hours/ cycle, conduct 10 cycle |
Vibration | Method514.6 | 5-500Hz, Vertical 7.7Grms, 40mins x 3axis |
Category 24 | ||
Shock | Method 516.6 | 20 Grms, 11ms, 3 axes |
Non-Operating Test MIL-STD-810 | ||
Low Temperature | Method 502.5 | -33°C, 4 hours, change rate:≦20°C/ Hour -15°C, 72hours (By request) |
High Temperature | Method 501.5 | +71°C, 4 hours, change rate:≦20°C/ Hour |
Procedure 1 | +68°C, 240 hours (By request) | |
Vibration | Method514.6 | 5-500Hz, Vertical 7.7Grms, 40mins x 3axis |
Shock | Method 516.6 | 20 Grms, 11ms, 3 axes |
Salt Fog | Method 509.7 | Salt Spray (50±5)g/L |
MIL-STD 461 | ||
Conducted Emissions | CE102 basic curve | 10kHz – 30MHz |
Power Leads | ||
Conducted Emissions | RE102-4 | 1.5HMz – 30MHz – 5GHz |
Electric Field | ||
Radiated Susceptibility | RS103 | 1.5 MHz – 3GHz, 50 V/m equal for all frequencies |
2MHz – 80MHz, 50 V/m equal for all frequencies | ||
Electric Field | 80MHz – 3GHz, 50 V/m equal for all frequencies | |
3GHz – 5GHz, 50 V/m equal for all frequencies | ||
Electrostatic Discharge | EN 61000-4-2 | Air DISCHARGE: 8 Kv, Contact discharge : 6kV |
Electromagnetic compatibility | EN61000-4-4 | Signal and DC Net: 1 kV |
Electromagnetic compatibility | EN61000-4-5 | Lead vs. ground potential 1Kv, ignal und DC Net: 1 kV |
Radio disturbance | EN55022 | Class A |
Electromagnetic compatibility | EN61000-4-3 | 10V/m |
Electromagnetic compatibility | EN 61000-4-5 | Lead vs. ground potential 1Kv, ignal und DC Net: 0.5 kV |
MIL-STD-1275 Specifications | ||
Steady State | 20V~33V | |
Surge Low | 20V~33V | |
Surge High | 18V/500ms |